Features:
DIP24 package with industry standard pinout
8:1(9-75Vdc) ultra-wide input range
Operating temperature range -40 - +85ā
No minimum load required
Comply to BS EN/EN55032 radiated Class A without additional components
High efficiency up to 87%
Protections: Short circuit (Continuous) / Overload / Over voltage / UVLO
Remote ON/OFF control (Optional)
3KVdc I/O isolation
3 years warranty
General Specification:
Ā Input Voltage Nominal 12V, 24V,36V,48V,72V (9 - 75V) Protection Fuse recommended. 4A Slow-Blow Type Short Circuit Protection Protection type : Continuous, automatic recovery Over Load Protection 110 - 230% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed Over Voltage Protection Protection type : Clamp by TVS diode Under Voltage Lockout Start-up voltage: 8.8Vdc Shutdown voltage: 8Vdc Withstand Voltage I/P-O/P:3KVdc Operating Temperature -40 - +85ā (Refer to "Derating Curve") Safety Standard EAC TP TC 020/2011 approved Dimension (LxWxH) 31.8 x 20.3 x 12.2mm